| DCV-1 | 0240.2187.06 | Documentation
of calibration values |
| NRVD-B2 | 0857.8908.02 | Analog
output, trigger input sweep frequency input input-/output option for
NRVD |
| NRVD-DKD | 1161.3242.02 | NRVD
DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with
device) |
| NRVD-S1 | 1029.2808.02 | Service
kit for NRVD |
| NRVS-S1 | 1029.2708.02 | Service
kit for NRVS and URV55 |
| NRV-Z15 | 1081.2305.02 | Power
sensor 50 Ohm 50 MHz - 40 GHz, 400 pW - 20 mW K(2.92 mm) male, 1.3 m (4
ft) cable |
| NRV-Z31 | 0857.9604.02 | Peak
power sensor 50 Ohm 30 MHz - 6 GHz, standard model 1 W - 20 mW |
| NRV-Z31 | 0857.9604.03 | Peak
power sensor 50 Ohm 30 MHz - 6 GHz, 1 W - 20 mW high speed model |
| NRV-Z31 | 0857.9604.04 | Peak
power sensor 50 Ohm 30 MHz - 6 GHz, TDMA model 1 W - 20 mW |
| NRV-Z32 | 1031.6807.04 | Peak
power sensor 50 Ohm 30 MHz - 6 GHz, 100 W - 2 W TDMA model |
| NRV-Z32 | 1031.6807.05 | Peak
power sensor 50 Ohm 30 MHz - 6 GHz, 100 W - 2 W universal model |
| NRV-Z33 | 1031.6507.03 | Peak
power sensor 50 Ohm 30 MHz - 6 GHz, 1 mW - 20 W high speed model |
| NRV-Z33 | 1031.6507.04 | Peak
power sensor 50 Ohm 30 MHz - 6 GHz, 1 mW - 20 W TDMA model |
| NRV-Z4 | 0828.3618.02 | Power
sensor 50 Ohm 100 kHz - 6 GHz, 100 pW - 20 mW N-connector male, 1.3 m (4
ft) cable |
| NRV-Z4 | 0828.3618.03 | Power
sensor 50 Ohm 100 kHz - 6 GHz, 100 pW - 20 mW N-connector male, 5 m (16
ft) cable |
| NRV-Z5 | 0828.3818.02 | Power
sensor 50 Ohm 100 kHz - 6 GHz, 10 nW - 500 mW N-connector male, 1.3 m (4
ft) cable |
| NRV-Z5 | 0828.3818.03 | Power
sensor 50 Ohm 100 kHz - 6 GHz, 10 nW - 500 mW N-connector male, 5 m (16
ft) cable |
| NRV-Z51 | 0857.9004.02 | Thermal
power sensor 50 Ohm 0 - 18 GHz, 1 W - 100 mW N-connector male, 1.3 m
(4 ft) cable |
| NRV-Z51 | 0857.9004.04 | Thermal
power sensor 50 Ohm 0 - 18 GHz, 1 W - 100 mW N-connector male, thermal
isolated |
| NRV-Z52 | 0857.9204.02 | Thermal
power sensor 50 Ohm 0 - 26.5 GHz, 1 W - 100 mW 3.5 mm male, 1.3 m (4
ft) cable |
| NRV-Z53 | 0858.0500.02 | Thermal
power sensor 50 Ohm 0 - 18 GHz, N-connector 100 W - 10 W |
| NRV-Z54 | 0858.0800.02 | Thermal
power sensor 50 Ohm 0 - 18 GHz, N-connector 300 W - 30 W |
| NRV-Z55 | 1081.2005.02 | Thermal
power sensor 50 Ohm 0 - 40 GHz, 1 W - 100 mW K (2.92 mm) male, 1.3 m
cable |
| NRV-Z6 | 0828.5010.03 | Power
sensor 50 Ohm 50 MHz - 26.5 GHz, 400 pW - 20 mW PC 3.5 mm male, 1.3 m (4
ft) cable |
| NRVD-C3 | 0857.8008.02.C3 | Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 1 additional depot calibration(s). |
| NRVD-C5 | 0857.8008.02.C5 | Five
years of calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibration(s). |
| NRVD-R3 | 0857.8008.02.R3 | Three
years of depot repair coverage, including re-calibration if necessary to
complete the repair. First year of repair coverage is provided by the
12-month new product warranty. |
| NRVD-R5 | 0857.8008.02.R5 | Five
years of depot repair coverage, including re-calibration if necessary to
complete the repair. First year of repair coverage is provided by the
12-month new product warranty. |