Anritsu S113B SiteMaster -
The Site Master is the instrument of choice for transmission line/antenna installation and maintenance. It is the best way to reduce maintenance expenses and improve quality. It replaces stacks of heavy, expensive and complex test equipment. The Site Master's frequency domain reflectometry technique allows it to find problems before they become catastrophic faults, thereby creating huge cost savings.
Specifications: Frequency range 5 to 1200 MHz Frequency accuracy (CW mode) 75 ppm Frequency resolution 10 kHz Display data points Selectable: 130,259,517 Immunity to interfering RF signals up to +10 dBm Return loss Range: 0 to 54 dB; Resolution: 0.01 dB SWR Range: 1 to 65 Resolution: 0.01 Cable loss Range: 0 to 20 dB Resolution: 0.01 dB Distance-to-fault Vertical range Return loss: 0 to 54 dB SWR: 1 to 65 Horizontal range (meter): 0 to (dp x resolution), where dp = 128, 256 or 512
Horizontal resolution, rectangular windowing resolution (meter): (1 .5 x 108)(Vp)/delta frequency Wattmeter (RF power monitor,Option 5) Display range: -80 to +80 dBm, 10 pW to 100 kW Detector range: -50 to +20 dBm, 10 mW to 100 mW Offset range: 0 to +60 dB Resolution: 0.1 dB Trace memory Up to 200 Instrument configuration 10 Test port connector Precision N female Maximum input RF OUT test port: +22 dBm RF IN test port: +10 dBm RF power detector: +20 dBm,50 ohms RF IN Spectrum Analyzer port : +20 dBm safe input, +27 dBm damage level Temperature Operating: 0 C to +50 C Storage: -20 C to +75 C