General Meters : Tektronix TCPA300

此产品是工厂翻新

TEKTRONIX TCPA300 Current Tester
放大图片TEKTRONIX TCPA300 Current Tester

Call 1-800-615-8378 for more information

Request a Quote

Check Rental Availability

租金测试设备


Features & Benefits

  • AC / DC Measurement Capabilities
  • DC – 100MHz, Current Probe Amplifier (TCPA300) Uses:
    • DC – 100MHz, 30 A DC (TCP312)
    • DC – 50MHz, 50 A DC(TCP305)
    • DC – 15MHz, 150 A DC (TCP303)
  • DC – 50MHz, Current Probe Amplifier (TCPA400) Uses:
    • DC – 2MHz, 750*1 A DC (TCP404XL) (500 A DC Continuous)
  • Automatic Scaling and Units*2 – Oscilloscope On-Screen Readout of Magnitude and Units Reduces Measurement Errors with No More Hand Calculations
  • AC / DC Input Coupling
  • Low Insertion Impedance Reduces Device Under Test Loading
  • Small Mechanical Package – Less Desktop Space, Easier Storage and Handling
  • Split-Core Construction Allows Easy Circuit Connection
  • Status Indicators Provide Visual Operating Status and Notification of Potential Error Conditions
  • Lower DC Drift and Noise Allows Improved Low Level Current Measurements
  • Certified for use in U.S., Canada, and Europe. Complies with applicable IEC standards.

Applications

  • Development and Analysis Solutions for Designers, Installers, and Service Personnel in Telecomm, Data Comm, Computer, and Semiconductor Power Electronics Environments For:
    • Power Supplies (Switching and Linear)
    • Semiconductor Devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
    • Power Inverters/Converters
    • Electronic Ballasts
    • Industrial /Consumer Electronics
    • Mobile Communications (Phone, Satellite, Relay Stations)
    • Motor Drives
    • Transportation Systems (Electronic Vehicles, Electric Trains, Locomotives, Avionics)

*1 Derated with Duty Cycle

*2 Requires a TDS TEKPROBE Oscilloscope or a TekConnect Oscilloscope with TCA-BNC

Increased performance and simplicity

The TCP300 and TCP400 series AC/DC Current Measurement family is a highly advanced current measurement system for today's current measurement needs. The split-core probes incorporate both transformer and Hall effect technology to provide broad bandwidth measurement capabilities from DC up to 100 MHz at current levels as low as 1 milliamp to thousands of amps (when used with CT4 current transformer). When connected to Tektronix TDS Oscilloscopes with TEKPROBE Level II or TekConnect (w/TCA-BNC) interfaces, current measurements and calculations are simple and easy.

Additional measurement power is available with add on software such as the TDSPWR2 power measurements package. With all this measurement power, current measurements have never been easier.

Meets today's AC/DC current measurement applications

The TCPA300 amplifier, when used with TCP312, TCP305, or TCP303 probes, provide a wide range of current measurement capability and spans the gap between low level milliamp measurements to very high current levels. These three probes provide current measurement capabilities of 30A, 50A, and 150A DC continuous. For even higher current levels, the TCPA400 amplifier with the TCP404XL current probe measures 500A DC continuous and 750A DC continuous, derated with duty cycle.

Higher frequency performance is available with the TCP312 w/TCPA300 providing ≥100 MHz bandwidth and a maximum current of 30A DC.

Measurement errors and manual calculations are now a thing of the past

With this new series of current measurement tools, automatic control and on-screen scaling and units is provided for users of Tektronix TDS3000, TDS500, TDS600, TDS700, TDS5000, TDS6000, and TDS7000B series oscilloscope systems. TDS series oscilloscopes provide on-screen scaling and units. Status LEDs quickly show you TCP300/400 series operating status or potential error conditions that may have caused measurement errors in the past.

The TCP300/TCP400 Current Measurement Systems seamlessly integrate with your TDS series oscilloscope and the TDSPWR2 software package to easily make those time consuming power measurements and calculations for you.

Even non-TEKPROBE systems can use the TCPA 300/400 series to make proper current measurements by simply multiplying the measured output voltage on the oscilloscope by the TCPA 300/400 series range setting.

  • 制造商: Tektronix
  • 模型: TCPA300