Wavetek 4106 GSM
All Wavetek 4100 series testers
can communicate with a PC via a
serial interface (RS-232-C) and
with all printers using the
standard Centronics port. Power is
provided from an external AC
power pack.
Features:
Generator output level
900 MHz: 44 to 110 dBm (+/-1.5 dBm) 4100
900 MHz: 44 to 110 dBm (+/-1 dBm) 4100S
1800/1900 MHz: 50 to 110 dBm (+/-1.5 dBm) 4100
1800/1900 MHz: 50 to 110 dBm (+/-1 dBm) 4100S
Generator frequency error
1 ppm
RF power measurements(burst)
+39 to 20 dBm (+/-1.5 dBm) usable up to +45 dBm
Frequency error measurement
within 5 kHz offset from carrier
900 MHz: +/-25 Hz, 1800/1900 MHz: +/-50 Hz
Phase error measurement
within measurement range 1.5 to 20 degrees rms
900MHz: +/-1.5 degrees rms, 1800/1900 MHz: +/-2.5 degrees rms
Interfaces
RS-232-C interface (serial) for exchanging data with PCs
Centronics interface (parallel) for commercially available printers
TNC jack for RF connection
Power pack connection