DESCRIPTION
The NEW Krohn-Hite Model 3004 Multichannel Filter/Amplifier Signal Conditioning System houses up to four filter/amplifier channels that provide cost effective signal conditioning over the frequency range from 1Hz to 200kHz. The 3004 is completely customizable. Cutoff frequency, filter type, input and output gains, and number of channels up to 4 are all determined by the customer. The 3004 is packaged in a 1U chassis with BNC input and output connections or mass termination connectors for digital control.
SPECIFICATIONS
FILTER CHARACTERISTICS
Cutoff Frequency Accuracy: 2% standard; 1% available. Temperature Coefficient: 0.05%/ C. Passband Response Deviation from Theoretical (non-inverting): Low-Pass: 1Hz to 50kHz, ±0.1dB; to 200kHz, ±0.2dB.
High-Pass (small signal, 0.4Vp-p): Input frequencies to 200kHz, ±0.1dB, -3dB point approximately 2.5MHz. Stopband Attenuation (Signal Rejection): Low-Pass: >100dB to 200kHz, >80dB to 1MHz.
High-Pass: >100dB. 2% standard; 1% available. Temperature Coefficient: 0.05%/ C.