DSO Oscilloscopes : LeCroy WaveMaster 808Zi

此产品是工厂翻新

Lecroy WaveMaster 808Zi
放大图片Lecroy WaveMaster 808Zi

Our Price:

US $79,490.00

Request a Quote

Check Rental Availability

租赁测试设备


8 GHz, 40 GS/s, 4ch, 10 Mpts/Ch DSO with 15.3" WXGA Color Display. 50 ohm and 1 Mohm Input

Innovative, Superior, Upgradeable

LeCroy has broken bandwidth barriers by combining custom designed SiGe high-speed components with 5th generation Digital Bandwidth Interleave (DBI) technology to achieve unprecedented real-time oscilloscope performance: 30 GHz, 80 GS/s, and 512 Mpts/Ch Analysis Memory.

Most Advanced Oscilloscope Platform

X-Stream II architecture provides 10–100x faster processing of long records, true 512 Mpts analysis memory, and instantaneous instrument responsiveness. When off-line data analysis is preferred, the LeCroy Serial Interface Bus (LSIB) provides up to 325 MB/s data transfer speeds. A 15.3" WXGA touchscreen display provides 50% more viewing area compared to other oscilloscopes in this class. Both 50 Ω and 1 MΩ inputs are standard on all oscilloscopes, as is support for all LeCroy probes (including passive probes) without the need for easy to lose external adapters or expensive power supplies.

Eye Doctor™ II Advanced Signal Integrity Tools Add Measurement Precision
  • Test Fixture and Cable De-embedding
  • Emphasis Emulation
  • Serial Data Channel Emulation
  • Receiver Equalization

Add precision to signal integrity measurements by allowing the subtraction of fixture effects, and the emulation of emphasis, serial data channels, and receiver DFE, FFE, and CTLE equalization effects while at the same time maintaining fast oscilloscope processing speed on unlimited record lengths. Re-capture design margin, better understand actual circuit performance, and perform compliance testing on emerging high-speed standards, such as PCIe Gen3, USB 3.0, SAS/SATA 6 Gb/s, that require emulation to ensure high field reliability and interoperability.

Superior Serial Data Analysis

SDA II Serial Data Analysis Software provides the highest confidence for serial data testing. Eye diagram analysis provides 100x faster capture of unit intervals (UI) in the eye diagram, and is enhanced with superior eye diagram analysis tools, such as lines of constant bit error rate (IsoBER ) and mask violation locators. Superior jitter decomposition methodologies and analysis tools provides more ability to understand problem behaviors in serial data systems. X-Stream II architecture leverages the superior tools through 10–100x faster processing and complete analysis processing of full record lengths, providing more insight faster.

5th Generation Digital Bandwidth Interleave (DBI)

As memory and sample rate can be interleaved, so can bandwidth. Using high- performance microwave and RF technologies, and high-speed processors and digital signal processing (DSP), LeCroy intelligently operates high-speed analog components comfortably within their rated bandwidth range while providing twice the four channel bandwidth on two channels. This approach offers better signal fidelity compared to “stretching” of components beyond their rated bandwidth. Best Investment Protection

From the perspective of bandwidth, sample rate, processing speed, responsiveness, display size, and range of capability, the WaveMaster 8 Zi platform is clearly superior and will remain so for many years to come. With the widest bandwidth upgrade range, an engineer who is working on 2nd generation technologies today can confidently know that WaveMaster 8 Zi will support 3rd or 4th generation technology needs several years from now.

X-Stream II Architecture
Optimized for Fast Throughput

X-Stream II architecture enables high throughput of data—even when the oscilloscope is performing multiple 100 Mpts (or larger) waveforms. X-Stream II uses variable waveform segment lengths to enable all processing intensive calculations to take place in fast CPU cache memory, thus improving calculation speed and efficiency. The result—10–100x faster processing compared to other oscilloscopes.

Optimized for Long Memory

X-Stream II essentially has no analysis memory length restrictions, regardless of analysis type, since the variable waveform segment length can always be limited to a size that can fit in CPU cache memory. Other oscilloscopes with conventional architectures cannot make this claim, and often have limitations on analysis memory of 5–20% the length of their acquisition memory under the best conditions.

Optimized for Responsiveness

By dynamically allocating buffers to maximize memory availability, the WaveMaster 8 Zi Series embodies the fastest front panel responsiveness. A built-in processing abort makes front panel control changes instant by stopping the current process and allowing new waveforms to be positioned or zoomed—all without a lengthy recalculation. Meanwhile, waveform previewing shows interim calculation results.

Freedom from Probing Limitations

WaveMaster 8 Zi excels in the way it offers general purpose utility never before seen in oscilloscopes from 4 to 30 GHz. All WaveMaster 8 Zi oscilloscopes contain selectable 50 Ω and 1 MΩ input capability and can be used with any LeCroy probe—passive or active—without requiring external adapters or power supplies. Use the two inputs per channel as a built-in switch matrix.

Complete System Debug

Understanding the relationships between different signals is vital to fast debug. Only WaveMaster 8 Zi combines the best of general purpose oscilloscopes (low-speed serial triggers and decoders, mixed signal capability, high impedance probing) with specialized 50 Ω inputs. This provides ability to 100% correlate high bandwidth signal activities or problems to low-speed events, such as low-speed serial data control words, power supply noise, or parallel data transmissions. Supported serial standards are 8b10b, PCIe, PCIe 2.0, SAS, SATA, XAUI, I2C, SPI CAN, LIN, UART-RS-232, and FlexRay.

More Triggers Isolate More Problems More Effectively

A full range of serial triggers (I2C, SPI, UART, RS-232, CAN, LIN, FlexRay) are available, providing capability to isolate events related to serial peripheral bus traffic. Most serial triggers contain powerful conditional DATA triggering to allow inclusion or exclusion of entire ranges of data values, which expedites understanding of how a range of serial bus traffic DATA values interact with other signals.

TriggerScan™

TriggerScan uses high-speed hardware triggering capability with persistence displays to capture only the signals of interest and provide answers up to 100x faster than other methods.

WaveScan™ Advanced Search and Analysis Finds Problems that Triggers Won’t Find

The best trigger won’t find all unusual events—a more powerful capability is sometimes needed. WaveScan provides the ability to locate unusual events in a single capture (i.e., capture and search) or “scan” for an event in many acquisitions over a long period of time. Select from more than 20 search modes (frequency, rise time, runt, duty cycle, etc.), apply a search condition and begin scanning. When an event is found, WaveScan highlights the error on screen and displays a table listing the errors.

Data Transfer Speeds 25–100x Faster

LeCroy’s Serial Interface Bus (LSIB) option enables direct connection to the PCI Express® x4 high-speed data bus in the oscilloscope to enable data transfer rates up to 325 MB/s. All that is required is installation of an optional LSIB card in the oscilloscope and the corresponding host board (card) for desktop (laptop) PC in the remote computer. Data transfer is easily enabled through a supplied application program interface (API).

Application Specific Solutions

In addition to the general purpose WaveShape Analysis tools, application specific solutions are available for Serial Data Compliance, Embedded Design, Digital Design, and Automotive. These packages extend the LeCroy standard measurement and analysis capabilities and expand your oscilloscope’s utility as your needs change.

  • Digital Filter Software Package (WM8Zi-DFP2)
  • Spectrum Analyzer Analysis Package (WM8Zi-SPECTRUM)
  • Mixed Signal Oscilloscope Option (MS-250/MS-500)
  • Jitter and Timing Analysis Package (WM8Zi-JTA2)
  • Eye Doctor II – Advanced Signal Integrity Tools (WM8Zi-EYEDRII)
  • 制造商: LeCroy
  • 模型: WaveMaster 808Zi
* 须要信息

请填妥以下表格让我们协助你取得你所需要的测量仪器
 *
 *






 *





本网站发送的所有电子邮件都含有该信息: 提醒: 为了您的利益和不被滥用,本网站发送的所有电子邮件都有记录以用于商店管理。如果您错误接收了该邮件,请发电子邮件到sales@testequipmentconnection.com

返回
Americas

United States USA & Canada: (800) 615-8378
 Florida: (407) 804-1299
Mexico Mexico 52-55-8421-4127
Chile Chile: 2-897-4335
Brazil Brazil: 301-32793
 Fax: 800-819-8378 / 407-804-1277
Skype: TestEquipmentConnection

Test Equipment Connection Corporation
30 Skyline Drive
Lake Mary, FL 32746 USA

TE Connection Asia, Ltd.
Unit 13, 16 / FL Fotan Industrial Centre
26-28 Au Pui Wan Street
Fotan Shatin N.T. Hong Kong

Test Equipment Connection Pte. Ltd.
6 Battery Road
#31-00 Standard Chartered Bank Building
Singapore 049909

Europe
United Kingdom United Kingdom:20-8144-7837
Ireland Ireland: 1-442-8376
Sweden Sweden: 46-46-288-61-42
Denmark Denmark: 369-92915
Finland Finland: 358-9-2316-3837
Asia/Pacific
China China: 86-136-3217-2095
Hong Kong Hong Kong: 852-2690-1360
Singapore Singapore: 65-6320-8596
Australia Australia: 61-2-8011-3687
Skype: TEConnectionAsia

This site chose VeriSign SSL for secure e-commerce and confidential communications.
ABOUT SSL CERTIFICATES website monitoring service