General Calibrators : Fluke 9640A

此产品是工厂翻新

Fluke 9640A Reference Source Generator
放大图片Fluke 9640A Reference Source Generator

Call 1-800-615-8378 for more information

Request a Quote

Check Rental Availability

The Fluke 9640A and 9640A-LPN Reference Generators can help you simplify the RF calibration process, by helping you to calibrate a broad range of RF test equipment:

  • Spectrum analyzers
  • Modulation meters and analyzers
  • RF power meters and sensors
  • Measurement receivers
  • Frequency counters
  • Attenuators
  • And more

High signal purity and low phase noise
The 9640A generates a pure sinusoidal signal with extremely low harmonics, spurious and residual modulations. This ensures that level accuracy will be maintained when you make measurements with wideband or narrow band detectors, or when the 9640A is intercomparing peak and RMS sensing instruments. You will avoid differences between the wideband/ narrow band and peak/RMS sensors, without requiring additional filters.

The importance of low phase noise on signal sources is often overlooked. The phase noise profiles of the Fluke 9640A are designed around the spectrum analyzer workload; the 9640A suits the vast majority, while the 9640A-LPN is capable of verifying the most demanding spectrum analyzers. Use the low phase noise specification to measure spectrum analyzer phase noise, close-in response and residual FM. Previous systems typically used two low noise signal generators to cover close-in and far-out measurements, or simply didn’t cover the far out (>100 kHz offset). Now you can handle both with a single 9640A-LPN.

Level accuracy and broad frequency coverage in one instrument
Calibration often involves use of several popular signal sources spanning a wide range of frequencies. Some of the most popular signal sources are now obsolete. You would normally need three signal generators, plus a power meter and sensors, to cover the entire frequency range of today’s workload with the required accuracy.

Whether your RF calibration workload has a frequency bandwidth of 4 GHz or 40 GHz, the Fluke 9640A handles the broadest portion of the RF calibration procedure in a cost effective solution.

Precision leveling head minimizes mismatch errors
A rugged, precision leveling head delivers the 9640A signals directly to the unit under test, minimizing losses, noise and mismatch errors, and maintaining the integrity of low-level signals. The head maintains signal precision and noise immunity throughout a 154 dB dynamic range, down to the very lowest levels at -130 dBm.

The leveling head reduces lead changes from 25 to just 5 during a typical calibration, extending unattended times in an automated system and reducing connector wear.

By integrating signal leveling and attenuation within the leveling head, the 9640A eliminates the need for separate, step attenuators, simplifying automation and reducing cost of ownership. It also eliminates the need to use an external power meter and sensors to characterize the output at different frequency and levels.

VSWR and mismatch errors are often the dominant source of measurement uncertainty in RF applications. Connecting the leveling head output directly to the load minimizes transmission line length and VSWR degradation due to cabling, allowing the full potential of its accuracy specifications to be realized at the load across the entire frequency range.

The standard 9640A and 9640A-LPN models are supplied with a 50 Ohm leveling head and the models have additional 75 Ohm leveling head. Mainframe and heads are calibrated together as a system.

Internal AM and FM modulation
The 9640A Reference Source’s internal modulation capability makes it suitable for applications that require precision modulation to be applied to the output signal, such as modulation analyzer calibration and spectrum analyzer sweep time testing using AM methods. You don’t need additional function generators as a low frequency modulation source – the 9640A delivers it all. Frequency modulation is available at rates up to 300 kHz for applications such as modulation analyzer testing. Amplitude modulation is available at depths of up to 99 % and rates up to 200 kHz.

Sweep function
RF applications often require a frequency sweep. The 9640A’s sweep functions simplify the application of manual legacy spectrum analyzer frequency response testing, as well as filter response.

External frequency reference input/output
Selectable external frequency reference input is available on the rear panel of the 9640A. The input allows you to lock the frequency output to an external reference, such as the Fluke 910R Rubidium Standard, for applications where high clock accuracy or use of a common reference frequency is important. The frequency reference output allows a UUT to be frequency locked to the 9640A internal reference clock. This configuration is often required to reduce frequency offset errors that may occur between the reference source and the UUT

HP 3335A and optional HP 8662A/8663A command emulation
The HP 3335A Synthesizer/Level Generator, discontinued long ago, has been an essential component in many users' RF calibration systems. Until now, there have been few alternatives to match its level and attenuation accuracy. The 9640A RF Reference Source matches or exceeds HP 3335A performance, and has a GPIB command interpreter capable of emulating the HP 3335A in a calibration system (including 75 Ohm applications).

Another long-discontinued instrument is the HP 8662A or HP 8663A low phase noise synthesizer. The 9640A-LPN is designed to match or exceed all HP 8662A/8663A performance and functionality within the calibration system. HP 8662 and HP 8663 GPIB command emulation is available as a “try before you buy” optional license key enabling on the 9640A-LPN.
  • 制造商: Fluke
  • 模型: 9640A
* 须要信息

请填妥以下表格让我们协助你取得你所需要的测量仪器
 *
 *






 *





本网站发送的所有电子邮件都含有该信息: 提醒: 为了您的利益和不被滥用,本网站发送的所有电子邮件都有记录以用于商店管理。如果您错误接收了该邮件,请发电子邮件到sales@testequipmentconnection.com

返回
Americas

United States USA & Canada: (800) 615-8378
 Florida: (407) 804-1299
Mexico Mexico 52-55-8421-4127
Chile Chile: 2-897-4335
Brazil Brazil: 301-32793
 Fax: 800-819-8378 / 407-804-1277
Skype: TestEquipmentConnection

Test Equipment Connection Corporation
30 Skyline Drive
Lake Mary, FL 32746 USA

TE Connection Asia, Ltd.
Unit 13, 16 / FL Fotan Industrial Centre
26-28 Au Pui Wan Street
Fotan Shatin N.T. Hong Kong

Test Equipment Connection Pte. Ltd.
6 Battery Road
#31-00 Standard Chartered Bank Building
Singapore 049909

Europe
United Kingdom United Kingdom:20-8144-7837
Ireland Ireland: 1-442-8376
Sweden Sweden: 46-46-288-61-42
Denmark Denmark: 369-92915
Finland Finland: 358-9-2316-3837
Asia/Pacific
China China: 86-136-3217-2095
Hong Kong Hong Kong: 852-2690-1360
Singapore Singapore: 65-6320-8596
Australia Australia: 61-2-8011-3687
Skype: TEConnectionAsia

This site chose VeriSign SSL for secure e-commerce and confidential communications.
ABOUT SSL CERTIFICATES website monitoring service