Signal Analyzers : Agilent-HP E5052A-810-820-1A7

此产品是工厂翻新

Agilent-HP E5052A-810-820-1A7
放大图片Agilent-HP E5052A-810-820-1A7

Call 1-800-615-8378 for more information

Request a Quote

Check Rental Availability

贸易在您的测试设备


The Agilent E5052A Signal Source Analyzer (SSA) is a new class of instrument that can evaluate the critical performance characteristics of nearly all types of RF and microwave signal sources. Agilent's goal in creating the SSA was to offer a single instrument that would significantly speed measurement times, and help R&D and manufacturing engineers in the wireless communications, broadband optical, aerospace/defense and electronics industries perform tests more accurately, and with unprecedented simplicity. The SSA also significantly lowers cost by eliminating the need to purchase multiple standalone instruments.

While the SSA follows the tradition of Agilent's popular 4352S VCO/PLL Signal Test System, which is designed to characterize voltage-controlled oscillators (VCOs) and PLL synthesizers, it addresses the limitations of the 4352S and offers new test capabilities that enable evaluation of a much broader range of signal source types.

Comprehensive Capabilities

The Agilent E5052A SSA makes four types of measurements:

  1. Frequency, power and DC current
  2. Transient measurements (frequency, phase and power versus time)
  3. Spectrum monitor
  4. Phase noise

The SSA has been designed to meet or exceed current and anticipated requirements for each measurement type. Frequency, power and DC current tests are facilitated by simultaneously measuring frequency, RF power and DC current consumption. DC tuning (control) voltage and DC power sweeps enable a variety of measurements, including:

  • Tuning sensitivity (frequency versus DC tuning voltage)
  • Frequency pushing (frequency versus DC power voltage)
  • RF power versus either DC tuning voltage or DC power voltage
  • DC current consumption versus either DC tuning voltage or DC power voltage

Two internal DC sources for device-under-test (DUT) power and control voltages are optimized for use with signal sources, which are very sensitive to noise on either tuning voltage or power voltage lines. Either DC control or power voltage can be swept with the result displayed on the instrument's LCD. There is no need to control the voltages with an external PC.

For versatile transient measurements that are necessary for characterizing PLL synthesizers and transmitters, the SSA employs frequency and phase demodulation as well as power measurements. Frequency, phase and power transients are simultaneously measured in heterodyne (narrowband) mode and direct (wideband) mode. Wideband mode is also available for wide frequency transient to enable designers to see more overall transient phenomenon. An external hardware trigger is accommodated by a rear-panel interface, and video and pre-trigger events can be observed before and after an event. Fine resolution is maintained even at the instrument's highest sample rate of 10 ns. The instrument's spectrum monitor function facilitates measurement of reference signal leakage (spurious) around the carrier and is useful because the signal source does not need to be reconnected.

Phase Noise Measurement Breakthrough

The E5052A SSA uses Agilent's proprietary cross correlation technique, which allows very low phase noise levels to be measured at all offsets from the carrier frequency without reducing measurement speed or compromising phase measurement performance. Cross correlation can remove the limitation posed by the noise floor of the reference source, while also lowering the usable noise floor by up to 20 dB. Cross correlation reduces the dependency of the measurement on low input power versus the available noise floor.

The cross correlation technique essentially cancels noise by employing two channels that have independent reference sources and through digital signal processing (DSP). If two signals are correlated and vector summed, the vector (amplitude and phase) of the two signals is emphasized. However, if two signals are uncorrelated, their vector sum is canceled, so the internal noise from references such as sources, analog-to-digital converters and mixers can be canceled. The amount of noise cancellation depends on the "number" of correlation and is based on root N (the number of correlation). Correlation of 10 times produces a 5 dB noise floor improvement, and 100 times correlation produces a 10 dB improvement.

The cross correlation technique traditionally has suffered from one primary limitation. It increased measurement time for data capture and computation, which itself depends on the difference between the phase noise of the DUT and that of the internal reference source. The SSA has solved this problem so that engineers can take advantage of the benefits of the technique. The instrument reduces measurement time by using a high-performance, 100 MHz (10 ns) digital-to-analog converter with a stepped Fast Fourier Transform (FFT) implemented with DSP.
The Agilent E5052A Signal Source Analyzer is a complete measurement solution for all types of signal sources. The SSA reduces the limitations of earlier multifunction instruments or "rack-and-stack" assemblages of instruments, and offers the advantage of not being limited to measuring only current devices. To achieve this, all major tests are performed at the highest achievable levels of performance, and the DUT is provided with a clean DC source. The SSA also works with external down converters that currently extend the top frequency range to 110 GHz. This feature helps ensure the SSA will not be limited by frequency in the future.


Key E5052A Specifications
Carrier frequency range: 10 MHz to 7 GHz (110 GHz with down converters)

Tests performed: Phase noise, frequency, power, DC current, spectrum monitor and frequency/power/phase transients

Phase noise test:

  • Offset frequencies: 1 Hz to 40 MHz
  • Phase noise sensitivity: >-178 dBc/Hz
  • Noise floor lowering method: Two-channel cross correlation

Frequency and power test:

  • Parameters: Frequency and power
  • Sweep type: DC power voltage or DC control voltage

Transient tests:

  • Parameters: Frequency, phase, and power versus time
  • Frequency resolution: 5 Hz to 7 kHz (Heterodyne mode)
  • Time resolution: 10 nanoseconds to 160 microseconds
  • Frequency transient range: (Heterodyne mode) 1.6 to 25.6 MHz
  • Pretrigger capability: Direct mode: 4.8 GHz max; -80% of time span or +1 s

DC tests:

  • Parameters: DC current (DUT power only)
  • Voltage/current range: Control: -15 to +35 VDC, 20 mA max; DUT power: 0 to +16 VDC, 80 mA max
The E5052B is the replacement product.
  • 制造商: Agilent-HP
  • 模型: E5052A-810-820-1A7
* 须要信息

请填妥以下表格让我们协助你取得你所需要的测量仪器
 *
 *






 *





本网站发送的所有电子邮件都含有该信息: 提醒: 为了您的利益和不被滥用,本网站发送的所有电子邮件都有记录以用于商店管理。如果您错误接收了该邮件,请发电子邮件到sales@testequipmentconnection.com

返回
Americas

United States USA & Canada: (800) 615-8378
 Florida: (407) 804-1299
Mexico Mexico 52-55-8421-4127
Chile Chile: 2-897-4335
Brazil Brazil: 301-32793
 Fax: 800-819-8378 / 407-804-1277
Skype: TestEquipmentConnection

Test Equipment Connection Corporation
30 Skyline Drive
Lake Mary, FL 32746 USA

TE Connection Asia, Ltd.
Unit 13, 16 / FL Fotan Industrial Centre
26-28 Au Pui Wan Street
Fotan Shatin N.T. Hong Kong

Test Equipment Connection Pte. Ltd.
6 Battery Road
#31-00 Standard Chartered Bank Building
Singapore 049909

Europe
United Kingdom United Kingdom:20-8144-7837
Ireland Ireland: 1-442-8376
Sweden Sweden: 46-46-288-61-42
Denmark Denmark: 369-92915
Finland Finland: 358-9-2316-3837
Asia/Pacific
China China: 86-136-3217-2095
Hong Kong Hong Kong: 852-2690-1360
Singapore Singapore: 65-6320-8596
Australia Australia: 61-2-8011-3687
Skype: TEConnectionAsia

This site chose VeriSign SSL for secure e-commerce and confidential communications.
ABOUT SSL CERTIFICATES website monitoring service