PowerPad Jr. Model 8230 w/MR193-BK (1000AAC/1400ADC)
8230
with MR193 Single-Phase Power Quality Analyzers The PowerPad Jr. Model 8230 is a
single-phase power quality analyzer that is easy-to-use, compact and
shock-resistant. It is intended for technicians and engineers to measure and
carry out diagnostic work and power quality work on single- or three-phase
balanced load networks. Users are able to obtain instant waveforms of an
electrical network s principal characteristics, and also monitor their
variation over a period of time. The multi-tasking measurement system
simultaneously handles all the measurement functions and waveform display of the
various magnitudes, detection, continuous recordings and their display without
any constraints.
The PowerPad Jr. Model 8230 with MR193 is supplied with a black
1000AAC/1400ADC current probe.
Features
Measures up to 660Vrms or VDC
Measures up to 6500AAC or 1400ADC (probe dependent)
Displays Min, Max and Average Volts and Amps, Crest Factor, Peak value and
K-Factor
Calculates and displays Watts, VARs and VA, Power Factor and Displacement
Power Factor for single-phase and balanced three-phase
Displays total harmonic distortion (THD-F and THD-R) for voltage and
current
Displays individual harmonic values and % for Volts and Amps through the
50th harmonic
Captures, displays and stores inrush current waveforms and statistics
Stores up to eight screen captures
Stores up to 1MB of trend recorded data
Configurable from DataView software or front panel
Download stored data to DataView software via optical with isolated USB
port
Captures up to 4096 alarm events using up to 10 different thresholds
Displays and records up to 17 different power quality parameters
Includes DataView software FREE.
Applications
Motor start-up analysis
Verification of power distribution circuits
Measurement and recording of power system quality (kW, VA, VAR)
Energy metering (kVAh, VARh, kWh)
In-plant troubleshooting of power distribution panels and individual
machinery
Determine harmonic problems originating from source or load