The Motorola R2600C Communication System Analyzer is designed specifically for the service and monitoring of radio communications equipment. The R2600C represents a breakthrough in simplicity of operation.
In place of numerous meters, keys and controls, the R2600C employs a large CRT display which simultaneously presents control and data displays.
A simplified front panel, utilizing soft keys, cursor movement keys, a numeric keypad, an analog tuning control and other dedicated function keys all combine to make the R2600C extremely easy to learn and very efficient to use.
*** The NT Version does not include the built-in tracking generator function of the R2600 Series.
Motorola R-2600C Performance Characteristics:
# Form Factor: Benchtop
# RF Communication Tester Type: Base Station,Mobile
# AMPS Communication Standard: Option
# CCITT Communication Standard: No
# CDMA Communication Standard: No
# CT3 Communication Standard: No
# DCS1800 Communication Standard: No
# DECT Communication Standard: No
# DMCA Communication Standard: No
# EAMPS Communication Standard: Option
# ETACS Communication Standard: Option
# FDMA Communication Standard: No
# GSM900 Communication Standard: No
# GSM1800 Communication Standard: No
# GSM1900 Communication Standard: No
# JTACS Communication Standard: Option
# NADC Communication Standard: No
# NAMPS Communication Standard: Option
# NMT450 Communication Standard: No
# NMT900 Communication Standard: No
# NTACS Communication Standard: Option
# PCS1900 Communication Standard: No
# PDC Communication Standard: No
# PHS Communication Standard: No
# TACS Communication Standard: Option
# TDMA Communication Standard: No
# Trunking Communication Standard: No
# Signal Generator Minimum Frequency: 400 kHz
# Signal Generator Maximum Frequency: 1 GHz
# Signal Generator Modulation: AM,FM,Pulse
# Signal Generator Resolution: 100 Hz
# Spectrum Analyzer Minimum Frequency: 400 kHz
# Tracking Generator Minimum Frequency: 400 kHz
# Tracking Generator Maximum Frequency: 1 GHz
# Oscilloscope Maximum Frequency: 50 kHz
# Voltmeter Maximum DC Voltage: 100 V
# Voltmeter Maximum AC Voltage: 70 V
# Voltmeter Maximum AC Frequency: 20 kHz
# Frequency Counter Minimum Frequency: 5 Hz
# Frequency Counter Maximum Frequency: 500 kHz
# Frequency Counter Input Resolution: 1 kHz
Motorola R-2600C Measurements/Features:
# Memory Recall Up to 30 Channel
# SINAD Meter Input: 0.1V-10VRMS
# Time Base Stability: 1ppm/yr
# Customised Test Set-ups
# Wattmeter Frequency: 400kHz-1GHz