The Guardian 1030S which combines both AC and DC Hipot tests and IR measurements with eight HV scan channels. All models have Open/Short Circuit detection and Load/Line regulation to ensure proper device connection and measurement integrity. The digital display and user friendly
controls allow test parameters and limits to be set without the high voltage activated. The Guardian 1030S AC/DC/IR/SC Hipot Tester has all of the features of the Guardian1030 plus eight HV Scan Channels for multi-point testing.
Features
AC Hipot Voltage 50 to 5000VAC, Output Current to 30mA
DC Hipot Voltage 50 to 6000VDC, Output Current to 10mA
IR Measurements from 100kk ohm to 50Gk ohm, Voltage: 50 to 1000VDC
Built-In 8 Channel Scanner for Multi-Point Testing (1030S)
Measure Real and Total Current
Programmable Hi/Lo Limits for Pass/Fail Testing
Ground Continuity Check with High Limit of 1 Ohm
Ability to Perform Multiple Tests in Sequence
Large LCD Display for Menu Programming and Test Results
Internal Storage and Recall of 99 Test Setups
Programmable Ramp and Test Times
Front Panel Lockout Prevents Changes to the Test Setup
Automatic Offset to Zero Out Residual Current
Fast Cutoff and Quick Discharge of Device Under Test