The Sentry 20+ AC/DC Hipot Tester (CE Mark) has all the features of the Sentry 10 Plus in addition to DC hipot capability. The test voltage is programmable from 50V to 6kV DC with a resolution of 1V. The current range is 0.1 microampere to 5mA.
Features
AC Hipot Voltage 50 to 5000V, Output Current to 20mA
DC Hipot Voltage 50 to 6000V, Output Current to 5mA
Programmable Ground Continuity Check, 0.1 to 5ohms
Programmable Ramp, Test, and Fall Times
Fast Cutoff and Discharge of Device Under Test
Programmable Hi/Lo Limits for Pass/Fail Testing
Large LCD Display for Menu Programming and Test Results
Internal Storage and Recall of 80 Test Setups
Ground Fault Interrupt Shutdown for Operator Safety
Front and Rear Panel Output Connections
Front Panel Lockout Prevents Changes to the Test Setup
Automatic Offset to Zero Out Stray Leakage Current