Network Analyzers : Agilent-Keysight N5244A

此产品是工厂翻新

Agilent N5244A
放大图片Agilent-Keysight N5244A

Call 1-800-615-8378 for more information

Request a Quote

Check Rental Availability

我们出售的高品质的测试设备


World's widest range of single-connection measurement applications

The PNA-X network analyzer is the world's most integrated and flexible single-connection microwave test engine for measuring active devices such as amplifiers, mixers, and frequency converters. You can choose from five frequency models to meet your specific device test needs: 13.5, 26.5, 43.5, 50, and 67 GHz. The PNA-X provides unrivaled configurability with a built-in second source, combiner, and internal signal-routing switches.

Replace racks and stacks

Reduce your equipment count by replacing racks and stacks of equipment with the PNA-X.

Applications:
  • S-parameters (CW and pulsed)
  • Noise figure
  • Gain compression
  • Intermodulation and harmonic distortion
  • Conversion gain/loss
  • True-differential stimulus
  • Millimeter-wave
  • Nonlinear waveform and X-parameter characterization
  • Antenna test
Key Features & Specifications
  • 10 MHz to 43.5 GHz
  • 2- or 4-ports with two built-in sources
  • 126 dB system and 129 receiver dynamic range, 32,001 points, 32 channels, 5 MHz IF bandwidth
  • High output power (+16 dBm), low harmonics (-60 dBc) and a wide power sweep range (41 dB)
  • Best dynamic accuracy: 0.1 dB compression with +15 dBm input power at the receiver
  • Low noise floor of -111 dBm at 10 Hz IF bandwidth

Options
008 - Pulsed-RF Measurements
010 - Time-domain measurements
020 - Add IF inputs
021 - Add pulse modulator to internal first source
022 - Add pulse modulator to internal second source
025 - Add four internal pulse generators
028 - Noise figure measurements using standard receivers
029 - Fully-Corrected Noise-Figure Measurements to 50 GHz
080 - Frequency offset measurements
082 - Scalar calibrated converter measurements
083 - Vector and scalar calibrated converter measurements
084 - Embedded LO measurements
086 - Gain compression measurements
087 - Intermodulation distortion measurements
088 - Source phase control
118 - Fast CW mode
1A7 - ISO 17025 compliant calibration
1CM - Rack mount kit for installation without handles
1CP - Rack mount kit for installation with handles
200 - 2 ports, single source
219 - Add extended power range and bias-tees to 2 port analyzer
224 - Add internal second source, combiner and mechanical switches to 2-port analyzer
301 - Application for use with standard CalPods
302 - Application for use with temperature-characterized CalPods
400 - 4 ports, dual source
419 - Add extended power range and bias-tees to 4 port analyzer
423 - Add internal combiner and mechanical switches to 4-port analyzer
460 - Integrated true-mode stimulus application
510 - Nonlinear component characterization
514 - Nonlinear x-parameters
518 - Nonlinear pulse envelope domain
520 - Arbitrary load impedance X-parameters
551 - N-port calibrated measurements
897 - Built-in performance test software for Agilent inclusive calibration, perpetual license
898 - Built-in performance test software for standards compliant calibration, perpetual license
A6J - ANSI Z540 compliant calibration
UK6 - Commercial calibration certificate with test data
  • 制造商: Agilent
  • 模型: N5244A